18 7 Dec 81 TITLE __________________________ Project No. ______________ Book NO. ______________ From Page No. _____________ CRT's 4000 Hr changeout limit in OMRS D (Pwr-up time) /25 mission #23 & 24 were btw 3000 & 4000. VE wans limit deleted - charge when degrad'n noted. Dick Bates 3N9 (MCOS)} x 7-2670 Don Conover (DDU)} 12/14/81 All 4 DEU's removed [[strikethrough]]& replaced[[/strikethrough]] over weekend. Called Bates: -ECLS MCR 5577 for airduct orifice mods; same units go back in after work. -CRT #21 in slot 4 w/ squiggly characters showed same problem in test unit; back to vendor. -S/N 13 goes into slot 4 (a flight unit) -No flt spares anywhere in program. All flt units except the 4 currently installed are back at vendor. - Gary Raines = E4D counterpart. -DEU's - 1 flight spare @ KSC To Page No._____ Witnessed & Understood by me, ____________________ Date _________ Invented by ____________________ Recorded by ____________________ Date ____________