Viewing page 170 of 287

This transcription has been completed. Contact us with corrections.

TABLE of TYPE SPECIFICATIONS.

[[8 Column Table]]

| TYPE | Military load Kgs. | Hours Gas | CEILING theoretic Meters | CEILING normal Meters. | SPEED, ceiling km/hour | SPEED sealevel km/hour | REMARKS |
| --- | --- | --- | --- | --- | --- | --- | --- | 
PURSUIT
| C. 1 | 220-270 | 2 1/2 - 3 | 9,000 | 7,000 | 240 | 120 | Monoplace pursuit for high altitudes. |
| c. 1 | 220-270 | 2 1/2 - 3 | 6,500 | 4,000 | 270 | 120 | Monoplace pursuit for low altitudes. |
PURSUIT AND RECONNAISSANCE
| C.Ap.2 | 400 | 4 | 8,500 | 7,000 | 200 | 110 | Biplace pursuit or reconnaissance. |
| C.An.2 | 400 | 4 | 6,000 | 3,000 | 190 | 90 | Biplace pursuit and night reconnaissance. |
OBSERVATION
| A. 2 | 450 | 3 | 6,000 | 1,000 to 3,000 | 200 | 90 | Biplace, C. A., and divisional |
| Ad. 2 | 450 | 3 | 6,000 | 1,000 to 3,000 | 200 | 90 | Biplace, C. A., and divisional |
| Ab. 2 | 350 | 2 1/2 | 4,500 | 1,000 | 180 | 80 | Armored biplace for divisional squadrons. |
BOMBARDMENT
| Bp. 2 | 580 | 7 | 7,500 | 5,000 | 190 | 90 | Biplace, day bombardment, long distance. |
| BS. 2 | 720 | 4 | 5,000 | 1,000 to 2,000 | 200 | 100 | Biplace bombardment or attack. |
| Bpr. 3 | 520 | 6 | 7,500 | 5,000 | 210 | 100 | Triplace of protection for the day bombardment. |
| Bn. 2 | 940 | 4 | 4,000 | 2,000 | 150 | 80 | Biplace, lightly loaded for day bombing and combat. |
| Bn. 4 | 2220 | 7 | 4,500 | 2,000 | 150 | 80 | Multiplace, heavily loaded, night bombardment, long distance. |
COLONIAL
| | 750 | 6 | 4,500 | 2,000 | 160 | 75| |

[[/8 Column Table]]

382

Transcription Notes:
Hyphenated words joined as per general rules. Formatting of table (particularly spacing) standardized. Removed empty columns to make it easier to read