Viewing page 25 of 71

This transcription has been completed. Contact us with corrections.

NRCC/SPAR
·1 set of 2 cameras (MID) are being analyzed 
(for planning purposes, assume no [[underlined]] data (flex) from 
STS-2)
·UNL arm data more important than LD arm data
·EE test in Canada: (qual EE) 1. GF not released 2. rigidization dropped: 850->650 (tried 4 times) 3. new EEEU installed

DAC problems
- lighting
- blurring (focus altered after [[check mark]]-out)
pan/tilt/zoom not known
cameras responded to firings (CCTV)
- correlation results ~1 week
·theodolite measurement (get one)
·false alarms in TEST mode during constrained inputs 
test
·100% current limits - SPAR will check on using these all the time
·PL ID 4 all the time - (delete PL ID 5 - lower rate)
·TAIL-ONLY DAP O.K. (Loaded with IECM)
ROLL - pulse width same
PITCH - 320->640 msec
delete yaw case
[UNL arm done on full DAP]