24 JAN 82 OMS DTD 482:
1. ADD: PRIMARY RJD'S - ON
2. ADD GIMBAL CHECK AFTER 2ND BURN:
STS-1 PROBLEM - SYNCHRO W ACTUATOR LOOSE ON SHAFT, RUBS ON STATOR. GENERIC PROBLEM, PRESENT IN ALL 8 GIMBAL ACTUATORS. FIX IS IN ACTUATORS AT KSC (SPACER ADDED BETWEEN STATOR + ROTOR), BUT THOSE WEREN'T INSTALLED.
-> SIGNATURE of PROBLEM CAN BE DETECTED BY MCC DURING GIMBAL CHECK... NOT BY CREW. CHECK IS DONE AFTER OMS-1 & OMS-2, SHOULD ALSO BE DONE AFTER LAST BURN ON-ORBIT (WITH TIME TO LOOK AT DATA BEFORE D/O)
[NOTE: HAS TO BE DONE IN 202 OR 302: OMS TVC ONLY PWR'D WHEN MNVR SPEC IS UP]