This transcription has been completed. Contact us with corrections.
• radio noise 1st night (speaker box minimized problem ← but still there) 2 types of noises: -UHF (including Indonesian flt cntls) -PRF of radar...coming thru with all A/G switches off - came thru ICOM •camera problems: cold case start-up introduces spikes into power supply (replicated at RCA) [PRCS interaction tests may have to be repeated on STS-4] •ICNCT gaging: SW counts pulses - overflows (SW DR opened against this) - there are procedural work-arounds (Erase counter, then start it again ... just don't let counter overflow) • schedule wireless battery change-out • Jack never did suit don/doff - doesn't feel it was req'd. • L5L temp sensor ← OX probably debonded (htr didn't respond as fast as others) • PLBD problem (day 2) - shouldn't be scheduled so late in day (w/ bad coverage) • N[[subscript]]2[[/subscript]] leak...real leak-only when cold- will be found & fixed •fired off fire [[?]] bottle into AV BAY 3 - no crew problem, no residuals. MER didn't check post-flt to make sure we still had protection through entry. •TACAN data ~1/3 of data expected because of swap of FD 3 & 4 (antenna reselection wasn't computed in time) - no noise fdback into wireless