![Transcription Center logo](/themes/custom/tc_theme/assets/image/logo.png)
This transcription has been completed. Contact us with corrections.
LONG SIM DEBRIEF RMS [[circled]]1[[/circled]] no I/O = no temp monitoring (htrs are quad redundant, ∴ no danger of failed on htr) Put MCIU bypass on SM variable parameter D/L ? → • 12.1s: LDB ↓ add to malf • memory read to look at that (2) grapple: EE mode bit (arm wouldn't limp) not put in by sim sup - Flt S/W or simulator? [[arrow]] Mem read in ref data (3) failures for which crew would cradle LOS → (back-up mode lost) check of back-up mode APC3 APU2 [[FU?]] TK ISOL VLV B (have vlv A) R OMS PR1 TVC → [use RCS fail cue card] MANF 2, 3, 4 redundancy (L & R) H[[subscript]]2[[\subscript]]O out of tanks B, C, D, E, F: water not flushed thru tanks since before STS-1 - cultures taken post STS-1, but it isn't great to drink. Best contingency procedures: [[circled]]1[[/circled]] hook to tk A [[circled]2[[/circled]] hook directly to fuel cell then [[circled]]3[[/circled]] hook to C, D, E, F RMS: no reason to cradle before RMS cooldown test (group 1) ascending node data was useful in CAP: "after SIR-A data take complete"....