28 JUNE - CFES (Charlie Walker @ JSC/MCC) • CFES SW PROMPTS ACTION, & IS INITIATED BY "POWER-ON"(SW MONITORS STATUS of SEVERAL SWITCHES/VLVS, & SEQUENCES ACCORDINGLY). IT PROMPTS WITH COMMAND "RUN X CMD, PGM". ONLY TIME THIS MSG COMES UP IS AT INITIALIZATION.... "X" REFLECTS THE NEXT SAMPLE THE SEQUENCER EXPECTS, & COUNTS UP. • ANY PROMPT STARTING WITH "CONTINUE" EXPECTS (& WAITS FOR) A "CMD, CONT" FROM KYBD • TO CLEAR A MSG FROM THE DISPLAY, "CMD, CLR" • 1ST RUN of EACH DAY INCLUDES AN INITIAL "START-UP," INCLUDING A "ZERO VOLTAGE CHECK" (RUNNING A SAMPLE UP THE COLUMN WITH NO VOLTAGE, TO GET A REFERENCE POINT) 6 JULY RMS MTG (HOMAN, MOSEL, KAIN, EHLERS) • NEED TO DEFINE POISE POSITIONS FOR ① REVERSE ② CAPTURE..... & POSSIBLY 2 REVERSE POSITIONS (ONE ABOVE COA5 [[?]], IN CONNECTION WITH THE PLUME SURVEY, ONE IN THE BAY - IN THE "QUIET ZONE"- TO SIMULATE WHERE WE INTEND TO DEPLOY FUTURE PL's) • NEED TO DEFINE SPAS-01 FOR BERTHING • KEEL CAMERA (GREAT FOR ORBITER X [[add a ^ above the X]] CUE FOR CSR/PLT) [SHOULD BE NO PROBLEM] (any impact of loss of plume survey data to prox ops?) [KANIPE was planning to use IECM data to validate SES....]