Action items from working group #15:
1) 80-01-70-25 IECM/RCS ops (in light of changes to RCS). Problem: during IECM ops, PRCS will be fired. A jet could fail on. Is monitoring a problem?
· when will jets be fired? If arm is stationary,"no problem" assuming brakes are effective if required
· this isn't a "monitoring of an auto sequence"
problem - its' a "what happens if PRCS
fails on" problem (with the corollary "what can I do about it?"). SPAR needs to answer this

2) 80-01-70-31 Provide FOD recommended single
mode vernier joint rate limits.
· vernier joint rate limits do not cause
"joint rate limiting" in manual modes vernier
· vernier rates used in FUR 128 and Phase V
are appropriate for single mode (cradling, etc.)
· larger question needs to be answered:
(1) What are appropriate vernier rate limits for loaded arm? Presumably this is payload dependent. How well can we monitor various rates? How fast do we typically move?