Viewing page 56 of 250

This transcription has been completed. Contact us with corrections.

"play" in them. The slightest touch causes +/-~5° oscillations (which don't damp quickly - several cycles at ~2hz (?))

(c) CCTV & pan/tilt units are covered with gold foil

(d) mounting to baseplate, & baseplate to orbiter seems stable - problem is in the unit itself

4. cable harnesses & freon loops. These will stick up several inches above the hinge line - though not above the MPM - and are located ~every 3-4 feet (there are ~10 such protrusions the length of the longeron).

Kain Ted Buras will have pictures (color) taken, with doors open, of CCTV, each longeron, & IECM left SFOM 16 for (1) Buras (2) Algire & Van Hooser

*use HP 9835 to get joint angles of arm at IECM grapple on STS-2/3

*get SPAR & NRCC comments on STS-2 & 3 DTO's to Ehlers

*DAC's : someone should check mounting & vibration

*Elbow CCTV … can this pan/tilt unit vibrate as much as bay CCTV's? If so, include this in MPM/launch dynamics