Viewing page 97 of 250

This transcription has been completed. Contact us with corrections.

22

3/28

✓- call JWB 
(1) min rates used during 130
(2) FUR 131 (who's got test plan?)
✓- Rob: FUR 131 test plan?

Problems

1. power switch - classified as crit 1, malf w.g. didn't press for fix. (FOD systems people + Peck will look at it + get back to us)

2. RI FMEA? RI: Functional criticality, not just HW crit. Close this issue after Q.P. looks it over

3. MG [[right arrow]] GPC failures?

4. fast jettison:
 
(1) close
(2) open new areas
(a) Q.P. ✓
(b) A14 ✓ (I'll send around)
(c) MPAD study ✓
                         
Q.P. brief > Friday + Mike Mullane  
{deadface- only MRL's not @ shoulder
{Step 1 always turn off RMS power [OSOP]

5. Crit 2 philosophy ? Bostick

6. JPC bite: close out ? Not hooked up, no bite (O.K.); filtercons?