2nd data run - IV/2 (65K deployment, no malfs) parameter comb. 1b: (1) cross-coupling was noticeable (2) arm did not achieve 1st pause pt of auto sequence (waited 4 1/2 minutes). • auto seq problem: tried to terminate 1st -> 2nd point portion: (1) AUTO STOP (2) [[1RM Entry]] : START PT -> 2 (it took, last pt still = 1) (3) still "ready") - AUTO PROCEED (4) it still tries for PT #2, not #3 try again, but this time: (1) START PT = 2; LAST PT = 1; " READY" ->(2) EXIT MODE (3) LAST PT UPDATES TO 2 UPON RE-ENTRY (& "READY" comes on) (4) AUTO "PROCEED" (5) ∴ it works! (goes to #3) [[margin note]]yes[[/margin note]] JR ✓- JR: is this like flight SW? • encoder false alarm: (LD, AUTO #5 -> 6) (1) diagnosed by malf procedures (2) tried to proceed, couldn't re-enter auto mode (at all... can't recycle encoder ✓) [[margin note]]encoder enable JR[[/margin note]] ✓- will re-cycling power (re-initializing I/O) re-set encoder flag ... or do we have to re-load SM?
Transcription Notes:
**Look at point (2) can't figure out first two words is it IRM early?
It looks like 1RM Entry