Viewing page 226 of 250

This transcription has been completed. Contact us with corrections.

2nd data run - IV/2 (65K deployment, no malfs)
parameter comb. 1b: (1) cross-coupling was noticeable (2) arm did not achieve 1st pause pt of auto sequence (waited 4 1/2 minutes).
•  auto seq problem: tried to terminate 1st -> 2nd point portion:
(1) AUTO STOP
(2) [[1RM Entry]] : START PT -> 2 (it took, last pt still = 1)
(3) still "ready") - AUTO PROCEED
(4) it still tries for PT #2, not #3
try again, but this time:
(1) START PT = 2; LAST PT = 1; " READY"
->(2) EXIT MODE
(3) LAST PT UPDATES TO 2 UPON RE-ENTRY (& "READY" comes on)
(4) AUTO "PROCEED"
(5) ∴ it works! (goes to #3)
[[margin note]]yes[[/margin note]] JR ✓- JR: is this like flight SW?
• encoder false alarm: (LD, AUTO #5 -> 6)
(1) diagnosed by malf procedures
(2) tried to proceed, couldn't re-enter auto mode (at all... can't recycle encoder ✓)
[[margin note]]encoder enable JR[[/margin note]] ✓- will re-cycling power (re-initializing I/O) re-set encoder flag ... or do we have to re-load SM?

Transcription Notes:
**Look at point (2) can't figure out first two words is it IRM early? It looks like 1RM Entry