14 Feb (KSC - closed mtg) Thiokol mtg 27 Jan (effect of cold) Mulloy (SRC project manager) • Recovery batteries } 2 concerns in early afternoon - only things brought up at MMT • hydrazine temp } • Mulloy not present @ 5:45 telecom when decision was made to have later technical telecom. Mason (Thiokol) • before 8:45 pm telecom - lots of difference of opinion at MTI • No T data on O-ring resiliency except "flight data" • No spec on joint T! went down to 47 degrees seal temp (MIL R 83248A is only test) on a static test...horiz, firing Scale test in gap (not joint) @ 30 degrees (no blow by) 2 @ 30 degrees, 2 @ room T (saw no blow by w/apparatus)
Transcription Notes:
everything looks good except the bracket encasing with "recovery batteries" and "hydra-zine temp" are all under one bracket.