Viewing page 86 of 204

This transcription has been completed. Contact us with corrections.

• seg in rain; out-of-roundness; hold-down bolt; O-ring close-out photo

• KSC inspection for crit 1 items?!?
(design center drives inspection...MSFC would put requirement into OMRSD)

• Is process for making joints adequate? Who's looking into this? (SRB Joint Team?)
└> not making recommendations (all-encompassing) on processing.

• solvent used near O-rings - rec. not be used in vicinity (used to clean pins)

• damage L aft seg taking off handling ring

• ~20 MRB actions (any waivers)

• segment left out in rain

• condensate is common

• ≥ 41B = present leak check
(check to 50 thru STS-7; to 100 for STS-8 & -9)