Project No. TITLE Book No. 3/10/82 65 From Page No. MLR POWER REQMTS PRE 1 bus sufficient (< 3 amps) 2 buses req'd [[**required]] for PWR tb (HALF tb will be gray). PROC Listen for stirring when PRE → PROC if not heard, converter may have shutdn [[**shutdown]]; recycle PRE → PROC 1 bus OK til [[**until]] heaters come on 1 htr on ~ 27 min after PROC 2nd htr ~ 11 hrs later w/ 2-3 htrs cycling 6.5-10.8 amps V1103 follow - ons: - Passed on Fish's squawk about "A" hatch lock-lever tab to Spern. He'll open an IPR. - Items for 1103 next flow: 1) Add venfic^ of SOP P = 5800-6200 psi 2) Perform full status list ck while on BATT 3) Check PLSS O2 P immediately post pwr ↑ and " pre pwr ↓ 4) Set MASTER VOL's to Max 5) Call out DCM cross-checks explicitly To: Roger Gillette (RI) or Tony Santiago (NASA) To Page No. Witnessed & Understood by me, Date Invented by Recorded by Date